Evaporative Cooling Pad 5090
The evaporative air coolers are equipped with best-in-class honeycomb cooling pads 5090. It is a revolution in honeycomb design.




The honeycomb cooling pad is treated with hardeners, preservatives, and special odorless binders to extend its life and durability.
The heated air is drawn in evaporative air coolers. When the air cooler passes through the wet honeycomb cooling pads, as it passes through the evaporative cooling pad, the water flowing through the honeycomb cooling pads absorbs heat from the air, causing the water to evaporate. It will produce cool, moist air.
By utilizing RTFANS’s HVLS Fans, air coolers, and other systems, we can establish a comfortable indoor environment, enabling people to rest and work more effectively.
Powerfoil Breeze knows when to spin and when to stay quiet—thanks to this commercial fan’s infrared motion sensor that automatically detects when people are active in your space and when they’re not. (And turns off after five minutes if your space is a ghost town!)
The specially engineered fluted structure of RTFANS Honeycomb cooling pads 5090 prevents sagging and clogging thus delivering cool air for a longer period of time.
RTFANS Honeycomb cooling pads 5090 have a unique structure that does not allow dust or dirt to settle on them.
RTFANS Honeycomb cooling pads 5090 can handle treble the air velocity over the same area, compared to any other type of Honeycomb cooling pads 5090.
Cover 1,000m² + with only 1.5kw!
Big industrial ceiling fans are energy efficient,cost-effective and can provide massive air movement in large industrial and commercial spaces.
Understanding Evaporative Cooling Pad 5090 Replacement: It's advised to perform annual cleaning of the pads, potentially twice a year—once before the cooling season and again afterward. Typically, you should plan to replace the pads every 2 to 3 years to ensure optimal performance.
Efficient Evaporative Cooler Pad 5090 Cleaning: Soak the pads in a 50/50 vinegar and water mix, followed by thorough drying. Simultaneously, cleanse the filter pad compartment with soap and water. To prevent mold, ensure the pads are dried weekly or monthly. Utilize natural sunlight to eliminate bacteria effectively.
Technical specifications
| MPN | KA-5090 |
|---|---|
| SKU | KA5090LL1 |
| Pad Height(mm) | As per Requirement |
| Pad Width(mm) | As per Requirement |
| Pad Depth(mm) | 50, 100, 150 |
| Flute Height(mm) | 5 |
| Groove Angle a | 45° |
| Groove Angle b | 45° |